Boulder City Council · Document
Attachment A - Applicant Plans and Written Statement
Regular Meeting, September 17, 2026 · item 5B: Consideration of a Nonconforming Use Review at 969 10th St. for the expansion of an existing duplex · 15 pages
This is the text extracted from the file, without its layout, tables, or images. Use the original for anything that matters.
PROJECT AREAS (EXISTING) A
EXISTING FAR
32.03 ft
14.61 ft
WIC
BATHROOM KITCHEN 3.58'
LIVING ROOM
WIC
UTILITY CLO HALL
UTILITY
STRG UP HALL DN
LIVING / DINING ROOM
45.95 ft
16.32 ft
STORAGE A
BEDROOM 3
BEDROOM 3
2.10 ft
BATHROOM
UP
BEDROOM 4
DN
B
CL 15.01 ft
2.03 ft
BEDROOM 2
BEDROOM 2
BEDROOM 1
BEDROOM 1 CL
CLOSET
A
PROJECT DESCRIPTION
2,618 SF
(E) LOWER LEVEL
299 SF
•TOTAL LOWER LEVEL AREA •UNF. MECHANICAL AREA •(Length of wall B (exposed more than 3') / (Length of wall A (exposed less than 3') + B) = 28% 28.6%
1,510 -133 +432
(E) MAIN LEVEL
PROPOSED FLOOR AREA RATIO: • 10% OF EXISTING F.A.R. (2,618 SF x .10 SF) •PROPOSED F.A.R. INCREASE (2,713 SF - 2,618 SF)
2,319 SF
•LIVING AREA •EXISTING GARAGE •SHED - 76 SF (EXEMPT FROM FAR) •FRONT PORCH •REAR DECK/ PORCH (ABOVE 30")
1,655 227 0 195 242
(E) UPPER LEVEL
0 SF
•UPPER LEVEL (unfinished) •MINUS STAIRWELL (not existing)
2,713 SF 261.8 SF
THIS PROJECT INVOLVES AN INTERIOR LEVEL 2 ALTERATION TO AN EXISTING SINGLE‑FAMILY RESIDENCE LOCATED AT 969 10TH STREET, BOULDER, COLORADO. THE SCOPE OF WORK INCLUDES THE INSTALLATION OF NEW ACCESS TO ATTIC STORAGE AND SEVERAL INTERIOR MODIFICATIONS. THE WORK PROPOSES THE CONSOLIDATION OF THE EXISTING UTILITY ROOM AND STORAGE ROOM TO CREATE SPACE FOR A NEW FOURTH BEDROOM AT THE BASEMENT LEVEL. ADDITIONALLY, THE PROJECT INCLUDES THE ADDITION OF A NEW CLOSET IN BEDROOM 2 AND THE REMODEL OF THE BATHROOM ADJACENT TO THE LIVING/DINING ROOM. ALL WORK IS CONFINED TO THE INTERIOR AND DOES NOT ALTER THE BUILDING FOOTPRINT OR EXTERIOR ENVELOPE.
95 SF
PROPOSED BLDG. COVERAGE:
2,294
REMAINING FLOOR AREA (F.A.R.)
637 SF
10th Street BUILDING PERMIT SET
Bulding Permit Set 969 10th st Boulder, CO 80302, usa PERMIT # BLD-SFD2025-00076
LEGAL DESCRIPTION ZONING CODE: RL-1 BLOCK: 10 LOT: 40 PARCEL: 146331312020
0 0
CLIENT: DAVID PERRY AND MIKE COSTELLO
32.13 ft
LOWER LEVEL - AS BUILT AREA PLAN
LOWER LEVEL - NEW CONSTRUCTION AREA PLAN
3/32" = 1'-0"
3/32" = 1'-0"
EXISTING BLDG. COVERAGE (1,655+ 227+76+195+242 = NOT COMPLIANT)
2,395 SF
ARCHITECT: K-Works Studio Katie Donahue, Katharina Hoerath 863 Santa Fe Drive Denver, CO 80204 T1: 212.203.5342 T2: 718.406.1779
MAXIMUM AREAS LOT SIZE: MAX. FLOOR AREA: BUILDING COVERAGE:
EXISTING GARAGE
6,250 SF 3,350 SF 2,300 SF
STRUCTURAL ENGINEER: Austin Duffy, EIT DL Eengineering, Inc 720-440-9450, ext 120 9100 W Jewell Ave Stc. 200 Lakewood, CO 8501232
EXISTING GARAGE
NEW PROJECT AREAS BICYCLE PARKING
DECK
W.I.C
EXISTING SHED
BEDROOM 5 W.I.C W.I.C
LAUNDRY
•TOTAL LOWER LEVEL AREA •UNF. MECHANICAL AREA •(Length of wall B) / (Length of wall A + B) = 28%
1,510 - 58 +432
MAIN LEVEL
KITCHEN DINING ROOM BATHROOM
UP
BEDROOM 2
374 SF
WC
BEDROOM 3
BEDROOM 3 DINING ROOM KITCHEN
LOWER LEVEL
DECK ABOVE 30" = 93 SF
WC
BATHROOM
PRIMARY BEDROOM
DN
2,713 SF
PANTRY
PANTRY BEDROOM 2
2,169 SF
•LIVING AREA •EXISTING GARAGE •FRONT PORCH •REAR DECK/ PORCH (ABOVE 30")
1,655 227 195 92
UPPER LEVEL
170
•UPPER LEVEL (converted) •MINUS STAIRWELL
238 -68
WIC FOYER
BEDROOM 1
BEDROOM 4
14' - 4 3/32"
7' - 4 3/4"
7' - 4 3/4" 21.3' N 0 3/32" = 1'-0"
Revisions: No. 00 01
Description PERMIT SUBMISSION REVISION 01
Date 06.15.25 07.22.25
02
REVISION 02
05.11.26
Seal & Signature
DN 29' - 2 1/2"
12' - 10 5/8"
AREAS TO BE COUNTED TOWARDS FAR
STORAGE
10 11 12 13 14 15 16 17 18
ATTIC
7' - 11 1/2"
3/32" = 1'-0"
13' - 7 7/8"
2' - 8" 3/32" = 1'-0"
10.7'
ENERGY COMPLIANCE SITE PLAN LANDSCAPE PLAN LOWER LEVEL DEMOLITION PLAN DIMENSIONS MAIN LEVEL DEMOLITION PLAN DIMENSIONS ATTIC LEVEL DEMOLITION PLAN LOWER LEVEL NEW CONSTRUCTION MAIN LEVEL NEW CONSTRUCTION ATTIC LEVEL NEW CONSTRUCTION BUILDING SECTIONS
PROJECT LOCATION:
8' - 8"
48' - 10 3/4"
MAIN LEVEL - NEW CONSTRUCTION AREA PLAN
5.3'
G-002 A-000 A-001 A-090 A-091 A-092 A-101 A-102 A-103 A-301
DN
MAIN LEVEL - AS BUILT AREA PLAN
0
2024 INTERNATIONAL RESIDENTIAL CODE 2024 INTERNATIONAL MECHANICAL CODE 2024 INTERNATIONAL PLUMBING CODE 2024 INTERNATIONAL FIRE CODE 2024 INTERNATIONAL FUEL GAS CODE 2024 INTERNATIONAL ENERGY CONSERVATION CODE 2024 INTERNATIONAL EXISTING BUILDING CODE 2018 2024 INTERNATIONAL CODE COUNCIL (ICC) 2024 CITY OF BOULDER ENERGY CONSERVATION CODE (COBECC) 2023 EDITION OF THE NFPA 70 NATIONAL ELECTRICAL CODE (NEC) AS AMENDED BY THE CITY OF BOULDER
DRAWING LIST
BEDROOM 1
9' - 9 1/8" DN
2,294 SF
ALL WORK SHALL COMPLY WITH LOCAL, STATE AND NATIONAL CODE:
EXISTING CHIMNEY TO REMAIN
DN
9 8 7 6 5 4 3 2 1
EAVES STORAGE
ATTIC ACCESS PANEL
COVER SHEET Project Number Issue Date Drawn by Checked by
2" AREAS NOT TO BE COUNTED TOWARDS FAR
05/01/2026
LIVING ROOM AREA OF 6' CEILING HEIGHT
7' - 11 17/32"
LIVING ROOM
PROPOSED BLDG. COVERAGE main building(1,768) + garage (227) + front porch (193) + front steps (14) + rear deck (92)
FOYER
LOCAL, STATE , & NATIONAL CODE COMPLIANCE
ATTIC LEVEL - AS BUILT AREA PLAN
ATTIC LEVEL - NEW CONSTRUCTION AREA PLAN
3/32" = 1'-0"
3/32" = 1'-0"
Project # Project Status Issue Date Author Checker
G-000 Scale 2025 K-Works Studio
As indicated
11/05/2026 21:35:38
DN
PROPOSED FAR
ENERGY COMPLIANCE ALTERATION LEVEL 2: MANDATORY AND PRESCRIPTIVE REQUIREMENTS PER R503
10th Street BUILDING PERMIT SET
Bulding Permit Set 969 10th st Boulder, CO 80302, usa PERMIT # BLD-SFD2025-00076
CLIENT: DAVID PERRY AND MIKE COSTELLO
ARCHITECT: K-Works Studio Katie Donahue, Katharina Hoerath 863 Santa Fe Drive Denver, CO 80204 T1: 212.203.5342 T2: 718.406.1779
STRUCTURAL ENGINEER: Austin Duffy, EIT DL Eengineering, Inc 720-440-9450, ext 120 9100 W Jewell Ave Stc. 200 Lakewood, CO 8501232
Revisions:
No. 00 01
Description PERMIT SUBMISSION REVISION 01
02
Date 06.15.25 07.22.25
REVISION 02
05.11.26
Seal & Signature
05/01/2026
Project # Project Status Issue Date Author Checker
Project Number Issue Date Drawn by Checked by
G-002 Scale
2025 K-Works Studio
11/05/2026 20:18:10
ENERGY COMPLIANCE
SITE PLAN GENERAL NOTES
2.
3. 4.
5. 6. 7. 8.
REFER TO SHEET G-0D1 FOR OVERALL PROJECT GENERAL NOTES, ABBREVIATIONS AND SYMBOLS. CONTRACTOR SHALL BE RESPONSEIBLE FOR GRADING OF SITE AND LOTS PERFORM EXCAVATION ACCORDING TO GOOD COMMON CONSTRUCTION PRACTICES TO THE LINES. GRADES AND ELEVATIONS INDICATED ON DRAWINGS PROVIDE SITE PREPARATION AS | SPECIFIED BY SOILS ENGINEER PROVIDE FOUNDATION DRAINAGE AS SPECIFIED BY SOILS ENGINEER AND CONTRACTOR (SEE THERMAL AND MOISTURE PROTECTION) APPROVED NUMBERS OR ADDRESSES SHOULD BE PROVIDED FOR ALL NEW BUILDINGS IN SUCH POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY TEMPORARY NUMBERS SHALL BE PLACED ON THE CONSTRUCTION METER AND DN THE FRONT OF THE HOUSE AT THE TIME OF ROUGH INSPECTIONS, LABEL CONSTRUCTION METERS WITH THE APPROVED ADDRESS PRIOR TO CALLING FOR INSPECTIONS CONTRACTOR TO COORDINATE ALL UTILITY DESIGN INSTALLATION AND SERVICES. CONTRACTOR TO ACCOMMODATE POSITIVE DRAINAGE AWAY FROM STRUCTURE AND ACROSS THE SITE, NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO FOUNDATION INSTALLATION. SLOPE GRADE AWAY FROM HOUSE AT ALL LOCATIONS: SLOPE A MIN. T' IN 10 HORIZONTAL FEET AWAY FROM HOUSE MINIMUM SLOPE TO BE 2%. MAXIMUM SLOPE TO BE 2%. CONTRACTOR TO PROVIDE PROPER COMPACTION OF ALL EXCAVATED & TRENCHED AREAS AT TIME OF BACKFILL. CONCRETE SIDEWALK IN RIGHT OF WAY TO MEET DENVER TRANSPORTATION REQUIREMENTS AS DETAILED ON THIS SHEET. CONTRACTOR SHALL FOLLOW CITY OF DENVER TREE PROTECTION STANDARDS IF REQUIRED FOR ROW TREES. EXISTING UNDERGROUND SEWER LINE TO BE REPLACED. ROUTED TO ALLEY
10th Street BUILDING PERMIT SET
Bulding Permit Set 969 10th st Boulder, CO 80302, usa PERMIT # BLD-SFD2025-00076
CLIENT: DAVID PERRY AND MIKE COSTELLO
ARCHITECT: K-Works Studio Katie Donahue, Katharina Hoerath 863 Santa Fe Drive Denver, CO 80204 T1: 212.203.5342 T2: 718.406.1779
STRUCTURAL ENGINEER: Austin Duffy, EIT DL Eengineering, Inc 720-440-9450, ext 120 9100 W Jewell Ave Stc. 200 Lakewood, CO 8501232
Revisions:
No. 00 01
Description PERMIT SUBMISSION REVISION 01
02
James Z. Gowan 2026.02.24 '00'07- 11:21:30
Date 06.15.25 07.22.25
REVISION 02
05.11.26
James Z. Gowan Seal & Signature
05/01/2026
SURVEY Project # Project Status Issue Date Author Checker
Project Number Issue Date Drawn by Checked by
G-005 Scale
2025 K-Works Studio
1 1/2" = 1'-0"
11/05/2026 20:18:16
1.
SITE IMPROVEMENTS:
SITE IMPROVEMENTS:
TRASH BINS
4.00'
50.00'
12.40'
12.40'
1.50'
15.00'
LOWER DECK
DN 5,523.00
PORTION OF DECK TO BE DEMOLISHED
9.80'
HIGH DECK
12.10'
21.40'
6.00'
STRUCTURAL ENGINEER: Austin Duffy, EIT DL Eengineering, Inc 720-440-9450, ext 120 9100 W Jewell Ave Stc. 200 Lakewood, CO 8501232
0.70'
14.60'
1.80' 3.00'
7.33' 0.70'
LOT 41
5,518.00
125.00'
125.00'
LOT 42
41.10'
5,519.80
TWO-STORY BRICK & FRAME W/BASEMENT
16.30'
41.10'
125.00'
TWO-STORY BRICK & FRAME W/BASEMENT
16.30'
ARCHITECT: K-Works Studio Katie Donahue, Katharina Hoerath 863 Santa Fe Drive Denver, CO 80204 T1: 212.203.5342 T2: 718.406.1779 5.30'
14.60'
1.80' 3.00'
5.30'
125.00'
LOT 41
CLIENT: DAVID PERRY AND MIKE COSTELLO
5,523.00
DN
12.10'
12.10'
7.80'
21.40'
5,521.10
NEW BICYCLE LOCKER, PER DRC 2-11(H)(2)(c). • PROVIDED W/ 5 ADJUSTABLE RACKS FOR (5) LONG TERM PARKING SPACES. • INT. TO BE MIN. 6' X 3', WITH 3' ACCESS DOOR. • EACH RACK PROVIDES 30" BICYCLE CLR. • 60" CLEARANCE PROVIDED BEHIND DOORS. • LOCATED LESS THAN 300' FROM ENTRY.
12.10'
5,521.10
SHED
PERMIT # BLD-SFD2025-00076
1.50'
HIGH DECK
LOWER DECK
Bulding Permit Set 969 10th st Boulder, CO 80302, usa
LOT 41
18.30'
18.30'
NEW LONG-TERM BICYLE PARKING INTO THE GARAGE TO BE PROVIDED WITH LOCKABLE DOOR AND ADEQUATE LIGHTING
1.50'
1.50'
BUILDING PERMIT SET
EXISTING BUSHES AND TREES TO REMAIN AND MAINTAINED.
FRAME GARAGE
LOT 41
10th Street
BROKEN FENCE PANEL TO BE REPLACED AS NEEDED
1.50'
GARAGE
SHED TO BE DEMOLISHED
50.00'
4.00'
TRASH BINS
15' ALLEY (PLAT)
15.00'
15' ALLEY (PLAT)
5,519.80
LOT 42
5,518.00
EXISTING METAL GATE TO REMAIN
Revisions: 15.00'
15.00'
5,523.60
32.10'
ASPHALT DRIVEWAY
7.33'
02 32.10'
REPLACE DAMAGED RAILING WITH NEW WOODEN RAILING - LIKE FOR LIKE
5,523.00
REVISION 02
05.11.26
6.00'
DN
NEW FRONT YARD LANDSCAPING IN COMPLIANCE WITH SECTION 9-9-12, B.R.C. 1981. LOW-WATER PLANTING BED WITH NATIVE SHRUBS AND PERENNIAL GRASSES (SUCH AS SERVICEBERRY, RABBITBRUSH, BLUE GRAMA, AND PENSTEMON)
32.50'
5,519.10
Date 06.15.25 07.22.25
5,523.00
REPAIR OF EXISTING ENTRY STAIRS.
DN
Description PERMIT SUBMISSION REVISION 01
5,519.10
32.50'
ASPHALT DRIVEWAY
No. 00 01
Seal & Signature
SEE LANDSCAPE PLAN A-001 FOR MORE DETAILS. 50.00'
50.00'
CONC. SIDEWALK
969 10TH STREET
05/01/2026
SITE PLAN
40.00'
40.00'
969 10TH STREET
Project # Project Status Issue Date Author Checker
Project Number Issue Date Drawn by
SITE PLAN - EXISTING 1/8" = 1'-0"
2 A-000
SITE PLAN - PROPOSED 1/8" = 1'-0"
Checked by
0
4'
8'
16'
A-000
N
1 A-000
0 1/8" = 1'-0"
2" Scale
2025 K-Works Studio
1/8" = 1'-0"
11/05/2026 20:18:24
CONC. SIDEWALK
50.00'
LANDSCAPE NOTES PLANTING WINDOWS: PLANTING IS NOT PERMITTED BETWEEN OCT 15–MAR 1 WITHOUT CITY APPROVAL. NON-CONTAINER STOCK SHALL NOT BE PLANTED JUN 1–SEP 1 WITHOUT APPROVAL. BARE ROOT STOCK MUST BE PLANTED BEFORE APR 30 AND PRIOR TO LEAF-OUT. DO NOT PLANT DURING FREEZING TEMPERATURES OR UNSUITABLE SITE CONDITIONS. ALL ADJACENT PAVING, GRADING, AND IRRIGATION MUST BE COMPLETED AND OPERATIONAL BEFORE PLANTING.
5,523.60
10th Street
SITE PREPARATION: ALL NEW OR DISTURBED PLANTING AREAS SHALL BE PREPARED IN ACCORDANCE WITH CITY OF BOULDER STANDARDS. SOIL SHALL BE TILLED TO A MINIMUM DEPTH OF 6 INCHES AND AMENDED AS NECESSARY TO SUPPORT HEALTHY PLANT GROWTH.
ASPHALT DRIVEWAY
BUILDING PERMIT SET 32.10'
MULCH: PROVIDE A MINIMUM 4" LAYER OF ORGANIC MULCH IN ALL PLANTING BEDS AND WITHIN A 3 FT DIAMETER AROUND NEW TREES IN TURF OR SEEDED AREAS. WEED BARRIER FABRIC IS NOT PERMITTED.
Bulding Permit Set 969 10th st Boulder, CO 80302, usa
ROCK/GRAVEL USE: REMOVE ROCK OR GRAVEL FROM UNDER STREET TREES AND REPLACE WITH ORGANIC MULCH. ROCK OR GRAVEL MULCH IS NOT PERMITTED IN PLANTING BEDS EXCEPT AS LIMITED DECORATIVE FEATURES (E.G., DRAINAGE SWALES) OR FOR PATHS/PATIOS.
TREE & UTILITY SEPARATION: NEW TREES SHALL BE LOCATED A MINIMUM OF 10 FT FROM WATER OR SEWER LINES, LIGHT POLES, AND OVERHEAD UTILITIES. NEW UTILITY LINES SHALL MAINTAIN A MINIMUM 10 FT CLEARANCE FROM EXISTING STREET TREES.
PERMIT # BLD-SFD2025-00076
5' - 0"
5,523.00
REPLACE EXISTING GRAVEL AND SHRUBS WITH LOCAL GRASSES AND PLANTS DN
NONCOMBUSTIBLE ZONE
NEW MANICURED AREA FOR DECORATIVE GRASSES IN TURF
NONCOMBUSTIBLE ZONE
4
5
4
6
CLIENT: DAVID PERRY AND MIKE COSTELLO
5 32.50'
TREE PROTECTION: EXISTING TREES WITHIN THE PUBLIC RIGHT-OF-WAY SHALL BE PROTECTED DURING CONSTRUCTION AND THROUGH THE WARRANTY PERIOD. MAINTENANCE SHALL BE PROVIDED TO ENSURE TREE HEALTH IN ACCORDANCE WITH CITY OF BOULDER DESIGN AND CONSTRUCTION STANDARDS.
5' - 0"
5' - 0"
IRRIGATION: INSTALL AN AUTOMATIC IRRIGATION SYSTEM FOR ALL NEW LANDSCAPING AND STREET TREES WHERE ONE DOES NOT EXIST. SYSTEMS SHALL INCLUDE SMART CONTROLLERS THAT ADJUST BASED ON WEATHER AND SOIL CONDITIONS.
6.00'
5,519.10
3 1
2
GRAVEL BORDER WITH SOME LARGE ROCKS PER REFERENCE IMAGE
6
2 4
5
4
ARCHITECT: K-Works Studio Katie Donahue, Katharina Hoerath 863 Santa Fe Drive Denver, CO 80204 T1: 212.203.5342 T2: 718.406.1779
3 2
5 1
2
STRUCTURAL ENGINEER: Austin Duffy, EIT DL Eengineering, Inc 720-440-9450, ext 120 9100 W Jewell Ave Stc. 200 Lakewood, CO 8501232
3
6
3
6
3
6
3
3
6
3
6
50.00'
CONC. SIDEWALK
969 10TH STREET Revisions:
1 A-001
LANDSCAPE PLAN - PROPOSED
No. 00 01
Description PERMIT SUBMISSION REVISION 01
02
Date 06.15.25 07.22.25
REVISION 02
05.11.26
3/16" = 1'-0"
Seal & Signature
05/01/2026
Project # Project Status Issue Date Author Checker
Project Number Issue Date Drawn by Checked by
DECORATIVE GRASSES IN TURF
DECORATIVE GRASSES IN GRAVEL
A-001
NEW RAILING FOR STAIR TO MATCH EXISTING - PAINTED WHITE TO MATCH EXISTING. Scale
2025 K-Works Studio
As indicated
11/05/2026 20:18:33
LANDSCAPE PLAN
DEMOLITION GENERAL NOTES 1. 2. 3. 4.
REFER TO SHEET G-001 FOR OVERALL PROJECT GENERAL NOTES, ABBREVIATIONS AND SYMBOLS. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS INCLUDING EXISTING UTILITY FEEDS, SETBACKS AND EASEMENTS. PROTECT ANY EXISTING EQUIPMENT, FIRE ALARM DEVICES, FIXTURES, FURNITURE, BUILDING ELEMENTS, ETC. TO REMAIN. PATCH ALL SURFACES TO REMAIN WHICH HAVE BEEN IMPACTED BY DEMOLITION WORK TO MATCH ADJACENT FINISH UNLESS OTHERWISE NOTED.
10th Street BUILDING PERMIT SET
Bulding Permit Set 969 10th st Boulder, CO 80302, usa PERMIT # BLD-SFD2025-00076
DASHED LINE INDICATES EXISTING ELEMENT TO BE REMOVED, RELOCATED OR MODIFIED; REFER TO NOTATION ON DRAWING SOLID LINE INDICATES EXISTING ELEMENT TO REMAIN
WIC
EXISTING WALL TO REMAIN
KITCHEN
EXISTING WALL TO BE REMOVED
BEDROOM 3 EXISTING DOOR TO REMAIN
CLIENT: DAVID PERRY AND MIKE COSTELLO
ARCHITECT: K-Works Studio Katie Donahue, Katharina Hoerath 863 Santa Fe Drive Denver, CO 80204 T1: 212.203.5342 T2: 718.406.1779
STRUCTURAL ENGINEER: Austin Duffy, EIT DL Eengineering, Inc 720-440-9450, ext 120 9100 W Jewell Ave Stc. 200 Lakewood, CO 8501232
EXISTING DOOR TO BE REMOVED
DEMOLITION LEGEND LIVING ROOM STORAGE
UTILITY UP
STRG
Revisions:
CLO
WIC
No. 00 01
HALL HALL
DN
Description PERMIT SUBMISSION REVISION 01
02
DN
Date 06.15.25 07.22.25
REVISION 02
05.11.26
CL
BEDROOM 1
BEDROOM 2
CLOSET Seal & Signature
1/4" = 1'-0"
2 A-090
LOWER LEVEL FLOOR PLAN - DEMOLITION
05/01/2026
1/4" = 1'-0"
LOWER LEVEL DEMOLITION PLAN DIMENSIONS
Project # Project Status Issue Date Author Checker
Project Number Issue Date Drawn by Checked by
0
2'
4'
8'
0 1/4" = 1'-0"
A-090
2" Scale
2025 K-Works Studio
As indicated
11/05/2026 20:18:40
LOWER LEVEL FLOOR PLAN - EXISTING
N
1 A-090
DEMOLITION GENERAL NOTES DN
1. 2. 3. 4.
REFER TO SHEET G-001 FOR OVERALL PROJECT GENERAL NOTES, ABBREVIATIONS AND SYMBOLS. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS INCLUDING EXISTING UTILITY FEEDS, SETBACKS AND EASEMENTS. PROTECT ANY EXISTING EQUIPMENT, FIRE ALARM DEVICES, FIXTURES, FURNITURE, BUILDING ELEMENTS, ETC. TO REMAIN. PATCH ALL SURFACES TO REMAIN WHICH HAVE BEEN IMPACTED BY DEMOLITION WORK TO MATCH ADJACENT FINISH UNLESS OTHERWISE NOTED.
10th Street BUILDING PERMIT SET
Bulding Permit Set 969 10th st Boulder, CO 80302, usa
BATHROOM
PERMIT # BLD-SFD2025-00076
PRIMARY BEDROOM
DEMOLITION LEGEND DASHED LINE INDICATES EXISTING ELEMENT TO BE REMOVED, RELOCATED OR MODIFIED; REFER TO NOTATION ON DRAWING
W.I.C LAUNDRY
SOLID LINE INDICATES EXISTING ELEMENT TO REMAIN
CLIENT: DAVID PERRY AND MIKE COSTELLO
EXISTING WALL TO REMAIN
5' - 0"
BEDROOM 3
4' - 11"
DEMOLITION OF EXISTING WALL SEGMENT TO ACCOMMODATE THE NEW BATHROOM LAYOUT KITCHEN
EXPANSION OF EXISTING WALL OPENING
EXISTING WALL TO BE REMOVED
ARCHITECT: K-Works Studio Katie Donahue, Katharina Hoerath 863 Santa Fe Drive Denver, CO 80204 T1: 212.203.5342 T2: 718.406.1779
EXISTING DOOR TO REMAIN
STRUCTURAL ENGINEER: Austin Duffy, EIT DL Eengineering, Inc 720-440-9450, ext 120 9100 W Jewell Ave Stc. 200 Lakewood, CO 8501232
2' - 9"
DINING ROOM
3' - 6"
4' - 10"
EXISTING DOOR TO BE REMOVED
3' - 8"
BEDROOM 2
FP
" -3
2' - 6"
3' 4' - 0"
2' - 8"
0' - 5" 2' - 8" 0' - 5"
3' - 8"
4' - 4"
BATHROOM
DEMOLITION OF EXISTING WALL SEGMENT TO ACCOMMODATE THE NEW STAIR INSTALLATION
1' - 5 3/4"
FIREPLACE TO REMAIN
0' - 8 3/4"
02
Date 06.15.25 07.22.25
REVISION 02
05.11.26
4' - 2"
0' - 4"
BEDROOM 1
CLOSURE OF EXISTING WALL OPENING FOR THE FORMATION OF THE NEW ROOM
Description PERMIT SUBMISSION REVISION 01
5' - 10"
LIVING ROOM
No. 00 01
0' - 10"
FOYER
Revisions:
0' - 4"
5' - 10"
3' - 6"
5' - 6"
4' - 9"
PANTRY
Seal & Signature
DN
DN
05/01/2026
MAIN LEVEL FLOOR PLAN - EXISTING 1/4" = 1'-0"
2 A-091
Project # Project Status Issue Date Author Checker
Project Number
MAIN LEVEL FLOOR PLAN - DEMOLITION
Issue
1/4" = 1'-0"
Date Drawn by Checked by
0
2'
4'
8'
A-091
N
1 A-091
0 1/4" = 1'-0"
2" Scale
2025 K-Works Studio
As indicated
11/05/2026 20:18:47
MAIN LEVEL DEMOLITION PLAN DIMENSIONS
DEMOLITION GENERAL NOTES. 1. 2. 3. 4.
REFER TO SHEET G-001 FOR OVERALL PROJECT GENERAL NOTES, ABBREVIATIONS AND SYMBOLS. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS INCLUDING EXISTING UTILITY FEEDS, SETBACKS AND EASEMENTS. PROTECT ANY EXISTING EQUIPMENT, FIRE ALARM DEVICES, FIXTURES, FURNITURE, BUILDING ELEMENTS, ETC. TO REMAIN. PATCH ALL SURFACES TO REMAIN WHICH HAVE BEEN IMPACTED BY DEMOLITION WORK TO MATCH ADJACENT FINISH UNLESS OTHERWISE NOTED..
10th Street BUILDING PERMIT SET
Bulding Permit Set 969 10th st Boulder, CO 80302, usa PERMIT # BLD-SFD2025-00076
DEMOLITION LEGEND DASHED LINE INDICATES EXISTING ELEMENT TO BE REMOVED, RELOCATED OR MODIFIED; REFER TO NOTATION ON DRAWING 30' - 8"
CLIENT: DAVID PERRY AND MIKE COSTELLO
SOLID LINE INDICATES EXISTING ELEMENT TO REMAIN EXISTING WALL TO REMAIN
INSIDE FACE OF WALL
INSIDE FACE OF WALL EXISTING WALL TO BE REMOVED
ARCHITECT: K-Works Studio Katie Donahue, Katharina Hoerath 863 Santa Fe Drive Denver, CO 80204 T1: 212.203.5342 T2: 718.406.1779
SELECTIVE DEMOLITION TO CREATE FLOOR OPENING FOR THE PROPOSED STAIR INSTALLATION
16' - 2"
13' - 9"
EXISTING DOOR TO REMAIN
EXISTING DOOR TO BE REMOVED
STRUCTURAL ENGINEER: Austin Duffy, EIT DL Eengineering, Inc 720-440-9450, ext 120 9100 W Jewell Ave Stc. 200 Lakewood, CO 8501232
10' - 4"
DEMOLISH ATTIC ACCESS PANEL
1' - 2"
2' - 8"
1' - 2" 44' - 6 13/16"
2' - 8"
13' - 11" 2' - 6"
DN
6' - 2"
2' - 6"
EXISTING CHIMNEY TO REMAIN
Revisions:
No. 00 01
Description PERMIT SUBMISSION REVISION 01
02
Date 06.15.25 07.22.25
REVISION 02
05.11.26
Seal & Signature
INSIDE FACE OF WALL
INSIDE FACE OF WALL
05/01/2026
Project # Project Status Issue Date Author Checker
Project Number
ATTIC LEVEL FLOOR PLAN EXISTING 1/4" = 1'-0"
2 A-092
Issue
ATTIC LEVEL FLOOR PLAN DEMOLITION
Date
1/4" = 1'-0"
Drawn by Checked by
0
2'
4'
8'
A-092
N
1 A-092
0 1/4" = 1'-0"
2" Scale
2025 K-Works Studio
As indicated
11/05/2026 20:18:52
ATTIC LEVEL DEMOLITION PLAN
FLOOR PLANS GENERAL NOTES 1.
2. 3. 4. 5. 6. 7. 8.
ALL WORK SHALL COMPLY WITH THE LATEST APPLICABLE BUILDING CODES, LOCAL AMENDMENTS, AND JURISDICTIONAL REQUIREMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFYING CODE REQUIREMENTS RELATED TO STRUCTURE, EGRESS, FIRE SAFETY, AND ACCESSIBILITY. CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE STARTING WORK. REPORT ANY DISCREPANCIES OR CONCEALED CONDITIONS TO THE ARCHITECT/OWNER BEFORE PROCEEDING. DO NOT CUT OR MODIFY EXISTING STRUCTURAL MEMBERS WITHOUT APPROVAL FROM A LICENSED STRUCTURAL ENGINEER. PROVIDE TEMPORARY SHORING AS REQUIRED DURING STAIR REMOVAL AND MEZZANINE WORK. PROTECT ALL EXISTING SYSTEMS AND FINISHES TO REMAIN. COORDINATE REROUTING OR MODIFICATION OF ANY MECHANICAL, ELECTRICAL, OR PLUMBING COMPONENTS. CONTRACTOR SHALL PROVIDE REQUIRED SUBMITTALS, INCLUDING PRODUCT DATA AND STAIR SHOP DRAWINGS, FOR APPROVAL BEFORE INSTALLATION. MAINTAIN SAFE ACCESS AND REQUIRED EGRESS ROUTES THROUGHOUT CONSTRUCTION. INSTALL FIRE BLOCKING, DRAFT STOPPING, AND ANY RATED ASSEMBLIES AS REQUIRED BY CODE. ENSURE SITE SAFETY IN ACCORDANCE WITH OSHA AND LOCAL REGULATIONS. MAINTAIN A CLEAN SITE AND REMOVE DEBRIS REGULARLY. CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL REQUIRED INSPECTIONS, AND UNCOVER WORK AT THEIR EXPENSE IF REQUESTED BY AUTHORITIES.
2
10th Street BUILDING PERMIT SET
Bulding Permit Set 969 10th st Boulder, CO 80302, usa PERMIT # BLD-SFD2025-00076
WALL TAGS:
A-301
NEW TUB AND PLUMBING FIXTURES
W-1 W-2
INTERIOR WALL INTERIOR WALL
CLIENT: DAVID PERRY AND MIKE COSTELLO
SEE A-401 FOR WALL DETAILS AREA SCHEDULE:
14' - 3"
ARCHITECT: K-Works Studio Katie Donahue, Katharina Hoerath 863 Santa Fe Drive Denver, CO 80204 T1: 212.203.5342 T2: 718.406.1779
BATHROOM
6' - 3"
NEW CONSTRUCTION LEGEND
8' - 11"
BEDROOM 3
EXISTING REMAIN GSF GSF GSF GSF
9' - 3"
9' - 7"
W/D STACKED
KITCHEN
AREA 1,494 1,498 52 496
NAME LOWER LEVEL: MAIN LEVEL: MAIN LEVEL DECK: ATTIC LEVEL:
3' - 5" 5' - 1"
9' - 8"
W-1
STRUCTURAL ENGINEER: Austin Duffy, EIT DL Eengineering, Inc 720-440-9450, ext 120 9100 W Jewell Ave Stc. 200 Lakewood, CO 8501232
8' - 9"
EXISTING WALL TO REMAIN
NEW WALL 15' - 6"
NOT IN SCOPE OF WORK
13' - 5"
D1
12' - 6"
LIVING / DINING ROOM
9' - 6"
1
UTILITY
13' - 8"
8' - 1"
W-1
10' - 10"
A-301
HVAC 5' - 8"
4' - 0"
W-1
UP
CLOSET W-1
Revisions:
No. 00 01
7' - 3"
2' - 0"
BEDROOM 4
D2
CORRIDOR
Description PERMIT SUBMISSION REVISION 01
02
DN
Date 06.15.25 07.22.25
REVISION 02
05.11.26
13' - 6"
BEDROOM 1
13' - 6"
BEDROOM 2 3' - 3"
13' - 6"
W-1
6' - 0"
9' - 4"
D2
11' - 2"
7' - 1"
CLOSET
2' - 0"
11' - 9"
Seal & Signature
05/01/2026
Project # Project Status Issue Date Author Checker
Project Number Issue Date
LOWER LEVEL FLOOR PLAN NEW CONSTRUCTION
Drawn by
1/4" = 1'-0"
Checked by
0
2'
4'
8'
A-101
N
1 A-101
0 1/4" = 1'-0"
2" Scale
2025 K-Works Studio
As indicated
11/05/2026 20:18:58
LOWER LEVEL NEW CONSTRUCTION
FLOOR PLANS GENERAL NOTES DN
DECK
1.
2
2.
A-301
3. 4. 5.
NEW TOILET W/ RELOCATED ROUGH PLUMBING
13' - 8" 3' - 10"
WC
11' - 6"
2' - 10"
SH
W.I.C
4' - 6"
5' - 0"
W.I.C
10' - 7"
AREA SCHEDULE:
4' - 11"
1 A-601
9' - 3"
ARCHITECT: K-Works Studio Katie Donahue, Katharina Hoerath 863 Santa Fe Drive Denver, CO 80204 T1: 212.203.5342 T2: 718.406.1779
STRUCTURAL ENGINEER: Austin Duffy, EIT DL Eengineering, Inc 720-440-9450, ext 120 9100 W Jewell Ave Stc. 200 Lakewood, CO 8501232
EXISTING WALL TO REMAIN
W-2 3' - 0"
NOT IN SCOPE OF WORK
UP
BATHROOM
D3
PANTRY
AS CLOSE AS POSSIBLE TO CHIMNEY
NEW PLUMBING LEGEND
EXISTING VENTLESS STACKED WASHER/ DRYER
11' - 0"
W-2
EXISTING REMAIN GSF GSF GSF GSF
LIKE FOR LIKE SINK REPLACEMENT
KITCHEN
2' - 6" 13' - 4"
3' - 1"
A-301
3' - 1"
1' - 5"
1
AREA 1,494 1,498 52 496
NEW WALL
6' - 2"
5' - 9"
W-2
EXISTING PLUMBING FIXTURES
NEW PLUMBING FIXTURES
DN
BEDROOM 2
W-1
Revisions:
W-1
No. 00 01
WIC
D1
EXISTING FIRE PLACE TO REMAIN.
Description PERMIT SUBMISSION REVISION 01
CLOSET
2' - 2"
02
Date 06.15.25 07.22.25
REVISION 02
05.11.26
11' - 5"
FOYER
BEDROOM 4
BEDROOM 1
D1
14' - 2"
W-1 14' - 4"
13' - 0"
Seal & Signature
DN
05/01/2026
Project # Project Status Issue Date Author Checker
Project Number Issue Date Drawn by
1 A-102
MAIN LEVEL FLOOR PLAN - NEW CONSTRUCTION 1/4" = 1'-0"
Checked by
0
2'
4'
8'
0 1/4" = 1'-0"
A-102
2" Scale
2025 K-Works Studio
As indicated
11/05/2026 20:19:04
MAIN LEVEL NEW CONSTRUCTION
N
EXISTING METAL TO REMAIN NEW FENCE TO GATE VISUALLY PROTECT RUBBISH AREA
PERMIT # BLD-SFD2025-00076
CLIENT: DAVID PERRY AND MIKE COSTELLO
SEE A-401 FOR WALL DETAILS
NEW CONSTRUCTION LEGEND 4' - 5"
9' - 2"
INTERIOR WALL INTERIOR WALL
NAME LOWER LEVEL: MAIN LEVEL: MAIN LEVEL DECK: ATTIC LEVEL:
14' - 10"
13' - 0"
W-2
13' - 11" 2' - 9"
W-1 W-2
7' - 5"
D3
NEW STAIR
Bulding Permit Set 969 10th st Boulder, CO 80302, usa
WALL TAGS:
NEW TOILET AND SING
WC
DINING ROOM
BUILDING PERMIT SET
SH
VENTILATION
BEDROOM 3
10th Street
2' - 10"
W-1
11' - 11"
7. 8.
W-1
2' - 10"
7' - 1"
BEDROOM 5
6.
ALL WORK SHALL COMPLY WITH THE LATEST APPLICABLE BUILDING CODES, LOCAL AMENDMENTS, AND JURISDICTIONAL REQUIREMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFYING CODE REQUIREMENTS RELATED TO STRUCTURE, EGRESS, FIRE SAFETY, AND ACCESSIBILITY. CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE STARTING WORK. REPORT ANY DISCREPANCIES OR CONCEALED CONDITIONS TO THE ARCHITECT/OWNER BEFORE PROCEEDING. DO NOT CUT OR MODIFY EXISTING STRUCTURAL MEMBERS WITHOUT APPROVAL FROM A LICENSED STRUCTURAL ENGINEER. PROVIDE TEMPORARY SHORING AS REQUIRED DURING STAIR REMOVAL AND MEZZANINE WORK. PROTECT ALL EXISTING SYSTEMS AND FINISHES TO REMAIN. COORDINATE REROUTING OR MODIFICATION OF ANY MECHANICAL, ELECTRICAL, OR PLUMBING COMPONENTS. CONTRACTOR SHALL PROVIDE REQUIRED SUBMITTALS, INCLUDING PRODUCT DATA AND STAIR SHOP DRAWINGS, FOR APPROVAL BEFORE INSTALLATION. MAINTAIN SAFE ACCESS AND REQUIRED EGRESS ROUTES THROUGHOUT CONSTRUCTION. INSTALL FIRE BLOCKING, DRAFT STOPPING, AND ANY RATED ASSEMBLIES AS REQUIRED BY CODE. ENSURE SITE SAFETY IN ACCORDANCE WITH OSHA AND LOCAL REGULATIONS. MAINTAIN A CLEAN SITE AND REMOVE DEBRIS REGULARLY. CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL REQUIRED INSPECTIONS, AND UNCOVER WORK AT THEIR EXPENSE IF REQUESTED BY AUTHORITIES.
FLOOR PLANS GENERAL NOTES 1.
2. 3. 4. 5. 6. 7. 8.
ALL WORK SHALL COMPLY WITH THE LATEST APPLICABLE BUILDING CODES, LOCAL AMENDMENTS, AND JURISDICTIONAL REQUIREMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFYING CODE REQUIREMENTS RELATED TO STRUCTURE, EGRESS, FIRE SAFETY, AND ACCESSIBILITY. CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE STARTING WORK. REPORT ANY DISCREPANCIES OR CONCEALED CONDITIONS TO THE ARCHITECT/OWNER BEFORE PROCEEDING. DO NOT CUT OR MODIFY EXISTING STRUCTURAL MEMBERS WITHOUT APPROVAL FROM A LICENSED STRUCTURAL ENGINEER. PROVIDE TEMPORARY SHORING AS REQUIRED DURING STAIR REMOVAL AND MEZZANINE WORK. PROTECT ALL EXISTING SYSTEMS AND FINISHES TO REMAIN. COORDINATE REROUTING OR MODIFICATION OF ANY MECHANICAL, ELECTRICAL, OR PLUMBING COMPONENTS. CONTRACTOR SHALL PROVIDE REQUIRED SUBMITTALS, INCLUDING PRODUCT DATA AND STAIR SHOP DRAWINGS, FOR APPROVAL BEFORE INSTALLATION. MAINTAIN SAFE ACCESS AND REQUIRED EGRESS ROUTES THROUGHOUT CONSTRUCTION. INSTALL FIRE BLOCKING, DRAFT STOPPING, AND ANY RATED ASSEMBLIES AS REQUIRED BY CODE. ENSURE SITE SAFETY IN ACCORDANCE WITH OSHA AND LOCAL REGULATIONS. MAINTAIN A CLEAN SITE AND REMOVE DEBRIS REGULARLY. CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL REQUIRED INSPECTIONS, AND UNCOVER WORK AT THEIR EXPENSE IF REQUESTED BY AUTHORITIES.
10th Street BUILDING PERMIT SET
Bulding Permit Set 969 10th st Boulder, CO 80302, usa PERMIT # BLD-SFD2025-00076
2 A-301
CLIENT: DAVID PERRY AND MIKE COSTELLO
ARCHITECT: K-Works Studio Katie Donahue, Katharina Hoerath 863 Santa Fe Drive Denver, CO 80204 T1: 212.203.5342 T2: 718.406.1779
24' - 3"
W-1
STORAGE
W-1 7' - 8"
W-1
NEW CONSTRUCTION LEGEND
W-1
STRUCTURAL ENGINEER: Austin Duffy, EIT DL Eengineering, Inc 720-440-9450, ext 120 9100 W Jewell Ave Stc. 200 Lakewood, CO 8501232
EXISTING WALL TO REMAIN
NEW WALL D1 DN
NOT IN SCOPE OF WORK
1 A-301 9
8
7
6
5
4
3
2
1
EXISTING CHIMNEY TO REMAIN 2' - 11" 2' - 11"
Revisions:
LIVING ROOM
No. 00 01
Description PERMIT SUBMISSION REVISION 01
02
Date 06.15.25 07.22.25
REVISION 02
05.11.26
EAVES STORAGE DOOR
EAVES STORAGE
Seal & Signature
05/01/2026
ATTIC LEVEL FLOOR PLAN - NEW CONSTRUCTION 1/4" = 1'-0"
Project # Project Status Issue Date Author Checker
Project Number Issue Date Drawn by
N 0
4'
8'
Checked by
16'
A-103 Scale
2025 K-Works Studio
As indicated
11/05/2026 20:19:09
1 A-103
ATTIC LEVEL NEW CONSTRUCTION
BUILDING SECTIONS GENERAL NOTES 1.
2. 3.
2 A-301
4.
ROOF 5543.6
5. 6.
FLOOR STRUCTURE
7. 8.
LIVING ROOM 6' - 8"
THERMAL ENVELOPE
ALL WORK SHALL COMPLY WITH THE LATEST APPLICABLE BUILDING CODES, LOCAL AMENDMENTS, AND JURISDICTIONAL REQUIREMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFYING CODE REQUIREMENTS RELATED TO STRUCTURE, EGRESS, FIRE SAFETY, AND ACCESSIBILITY. CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE STARTING WORK. REPORT ANY DISCREPANCIES OR CONCEALED CONDITIONS TO THE ARCHITECT/OWNER BEFORE PROCEEDING. DO NOT CUT OR MODIFY EXISTING STRUCTURAL MEMBERS WITHOUT APPROVAL FROM A LICENSED STRUCTURAL ENGINEER. PROVIDE TEMPORARY SHORING AS REQUIRED DURING STAIR REMOVAL AND MEZZANINE WORK. PROTECT ALL EXISTING SYSTEMS AND FINISHES TO REMAIN. COORDINATE REROUTING OR MODIFICATION OF ANY MECHANICAL, ELECTRICAL, OR PLUMBING COMPONENTS. CONTRACTOR SHALL PROVIDE REQUIRED SUBMITTALS, INCLUDING PRODUCT DATA AND STAIR SHOP DRAWINGS, FOR APPROVAL BEFORE INSTALLATION. MAINTAIN SAFE ACCESS AND REQUIRED EGRESS ROUTES THROUGHOUT CONSTRUCTION. INSTALL FIRE BLOCKING, DRAFT STOPPING, AND ANY RATED ASSEMBLIES AS REQUIRED BY CODE. ENSURE SITE SAFETY IN ACCORDANCE WITH OSHA AND LOCAL REGULATIONS. MAINTAIN A CLEAN SITE AND REMOVE DEBRIS REGULARLY. CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL REQUIRED INSPECTIONS, AND UNCOVER WORK AT THEIR EXPENSE IF REQUESTED BY AUTHORITIES.
10th Street BUILDING PERMIT SET
Bulding Permit Set 969 10th st Boulder, CO 80302, usa PERMIT # BLD-SFD2025-00076
DOORS GENERAL NOTES UPPER LEVEL 5533.8
1. 2.
REFER TO SHEET G-001 FOR OVERALL PROJECT GENERAL NOTES, ABBREVIATIONS AND SYMBOLS. REFERENCE FLOOR PLANS FOR ALL DOOR LOCATIONS CLIENT: DAVID PERRY AND MIKE COSTELLO
NEW WET WALL
WALL TAGS:
BEDROOM 2
BATHROOM W-1 W-2
W-2
EXISTING WALL
ARCHITECT: K-Works Studio Katie Donahue, Katharina Hoerath 863 Santa Fe Drive Denver, CO 80204 T1: 212.203.5342 T2: 718.406.1779
INTERIOR WALL INTERIOR WALL
0'
4' - 4"
2' - 5"
MAIN LEVEL 5523.6
" -6
GROUND LEVEL 5519.1
BEDROOM 4
RIGID INSULATION TAPED AT SEAMS, FOAMED AT PERIMETER
5/8" TYPE 'X' GYP. BD. OVER STUD WALL
R60 FOAM INSULATION BETWEEN EXISTING JOINTS
LOWER LEVEL 5514.8
1 A-301
STRUCTURAL ENGINEER: Austin Duffy, EIT DL Eengineering, Inc 720-440-9450, ext 120 9100 W Jewell Ave Stc. 200 Lakewood, CO 8501232
R 13 - 3 1/2" THICK BATT INSULATION
TRASVERSAL SECTION 1/4" = 1'-0"
5 A-301
4 A-301
ROOF SECTION DETAIL 1/2" = 1'-0"
W2-INTERIOR WALL 1" = 1'-0"
Revisions:
1 A-301
EAVES STORAGE DOOR
ROOF 5543.6
MARK D-01
DOOR SCHEDULE WIDTH HEIGHT HARDWARE QUANTITY ROOM NAME STORAGE 3' - 0" 6' - 8" MORTISE LOCK 1
No. 00 01
Description PERMIT SUBMISSION REVISION 01
02
Date 06.15.25 07.22.25
REVISION 02
05.11.26
SEE SCHEDULE
0' - 8" 3' - 0"
LIVING ROOM
SEE SCHEDULE
UPPER LEVEL 5533.8
PORCH DINING ROOM
FOYER
Seal & Signature
BEDROOM 5
KITCHEN
LIVING / DINING ROOM
CORRIDOR
MAIN LEVEL 5523.6
FLOOR LEVEL
3' - 3"
2' - 5"
5,523.00
05/01/2026
GROUND LEVEL 5519.1
BUILDING SECTIONS
LOWER LEVEL 5514.8
SEE SCHEDULE
Project # Project Status Issue Date Author Checker
Project Number Issue Date Drawn by
2 A-301
LONGITUDINAL SECTION
Checked by
A-301
1/4" = 1'-0" Scale
2025 K-Works Studio
As indicated
11/05/2026 20:19:23
D-01
WORKS STUDIO Architecture & Design LUR Application Narrative 969 10th St, Boulder, CO 80302, USA
Project Intent Reconfiguring interior spaces to add additional bedrooms and converting the existing attic space into habitable floor area. Project Narrative The proposed project consists of interior renovations to an existing duplex located at 969 10th Street in Boulder, 80302, Colorado. The scope of work includes reconfiguring interior spaces to add additional bedrooms and converting the existing attic space into habitable floor area. No new dwelling units are proposed, and the exterior building footprint will remain unchanged.
Criteria for Review: 9-2-15. - Use Review (e): Consistency with Zoning and Nonconformity The subject property at 969 10th Street is an existing duplex that is legally established but nonconforming with respect to density. The proposed interior renovations do not alter the number of dwelling units and do not introduce a new use. The project is therefore consistent with the existing nonconforming status of the property.
(1) Rationale The proposed interior renovation and attic conversion at 969 10th Street provide a direct benefit to the surrounding neighborhood by improving the safety, functionality, and long-term viability of an existing residential duplex without expanding the building footprint or introducing a new use. By better utilizing underused attic space, the project increases housing capacity within the existing structure, reducing pressure for larger additions or redevelopment that could create greater neighborhood impacts, while maintaining compatibility with surrounding residential uses and providing a stable transition between varying residential intensities. The project directly supports Boulder Valley Comprehensive Plan policies that encourage efficient use of existing housing stock, sustainable infill development, and increased housing opportunities, while minimizing environmental and infrastructure impacts. As a legally established duplex that is nonconforming with respect to density, the proposed improvements constitute a permitted modification under Section 9-2-15(f) and comply with the criteria for expansion of a nonconforming use without increasing the degree of nonconformity.
(2) Compatibility The proposed interior renovations and attic conversion will not alter the exterior massing or scale of the building and will therefore remain compatible with the surrounding neighborhood. By working within the existing structure, the project minimizes potential impacts related to privacy, noise, and visual character. The use and intensity of the property will remain consistent with other nearby 1 Jan. 17th, 2026
WORKS STUDIO Architecture & Design LUR Application Narrative 969 10th St, Boulder, CO 80302, USA residential properties. We feel that the additional bedrooms is an insubstantial impact to the neighborhood, which is already comprised of multiple Duplex and Triplex Units.
(3) Infrastructure As compared to development permitted under Section 9-6-1, “Schedule of Permitted Land Uses,” B.R.C. 1981, and the existing level of impact of the nonconforming duplex, the proposed interior renovations and attic conversion at 969 10th Street will not significantly or adversely affect surrounding infrastructure, including water, wastewater, storm drainage, and streets, as no new dwelling units or building footprint expansion are proposed and all work occurs within the existing structure. While one additional bathroom is proposed, this results from dividing an existing large bathroom into two smaller bathrooms, and the overall plumbing fixture count remains comparable to existing conditions. As such, the project will not create a meaningful increase in demand on water or wastewater utilities. Overall, the proposed improvements represent a modest and efficient use of existing infrastructure and are substantially less impactful than development permitted outright in the zoning district.
(5) Character of Area The proposed renovations will not change the predominant character of the surrounding area. Because the work is limited to interior modifications and attic conversion, the exterior appearance of the building will remain unchanged, maintaining consistency with the established residential character of the neighborhood. We are proposing to improve landscaping in the front as well as improving the conditions of the existing steps leading to the front door.
(6) Conversion of Dwelling Units to Nonresidential Units The project does not involve the conversion of any dwelling units to nonresidential use. All proposed work remains residential in nature.
Criteria for Review: 9-2-15. – Additional Criteria for Expansion of a Nonconforming Use (f): (1) Reasonable Measures Required All reasonable measures have been taken to reduce or alleviate the effects of the existing nonconformity. By utilizing existing attic space and performing interior renovations, the project avoids expansion of the building footprint, minimizes construction impacts, and does not introduce new external impacts such as increased noise, glare, or traffic.
(2) Reduction in Nonconformity / Improvement of Appearance
2 Jan. 17th, 2026
WORKS STUDIO Architecture & Design LUR Application Narrative 969 10th St, Boulder, CO 80302, USA The proposed interior renovations and attic conversion improve the functionality and habitability of the existing nonconforming duplex without increasing the degree of nonconformity. In addition, the project includes modest exterior improvements that enhance the physical appearance of the site, including new front yard landscaping in compliance with Section 9-9-12, B.R.C. 1981, consisting of a low-water planting bed with native shrubs and perennial grasses (such as serviceberry, rabbitbrush, blue grama, and penstemon). Improvements to the entry stairs will further enhance pedestrian access and streetscape character, thereby satisfying the intent of this criterion. Additionally, four bike racks will be installed in the garage.
(3) Compliance with This Title / Exceptions The proposed changes comply with all applicable requirements of the Boulder Revised Code, except as related to the existing nonconforming density. No zoning variances are requested as part of this application.
(4) Cannot Reasonably Be Made Conforming The property cannot reasonably be made conforming with current density standards without the removal of an existing dwelling unit. The proposed interior renovations and attic conversion allow for continued use of the legally established duplex without exacerbating the existing nonconformity.
(5) No Increase in Floor Area Over Ten Percent The conversion of attic space to habitable floor area will not result in a cumulative increase in floor area of more than ten percent of the existing structure. The project does not alter the building footprint, FAR, or site coverage.
(6) Approving Authority May Grant Zoning Variances No zoning variances are requested as part of this application.
Please let us know if any additional information is required. Sincerely,
Katharina Hoerath K WORKS STUDIO
3 Jan. 17th, 2026