Attachment C - 5083 Cottonwood Dr - Utility Connection Plan

Regular Meeting, August 6, 2026 · item 4C: Outside City Utility Permit request for the property located at 5083 Cottonwood Dr. (case no. LUR2026-00022) · 1 page

Open the original file

This is the text extracted from the file, without its layout, tables, or images. Use the original for anything that matters.

N

LEGEND

PROPERTY LINE RIGHT-OF-WAY LINE

⊕

NOTES

EASEMENT LINE

1. UTILITIES SHALL COMPLY WITH THE CITY OF BOULDER

EX. WATER MAIN (6" C.I.)

DESIGN AND CONSTRUCTION STANDARDS. FND. #4 REBAR EL: 5178.7'

2. CONTRACTOR SHALL CALL 811 (UTILITY NOTIFICATION

EX. SEWER MAIN (8" V.C.P.)

CENTER OF COLORADO) MINIMUM 72 HOURS BEFORE

EX. SEWER STUB

'

.13

EXCAVATION.

'0

9 S5

3. ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY REQUIRES

°11

0"W

44

PROP. WATER SVC. (3/4" TYPE K Cu)

A CITY OF BOULDER RIGHT-OF-WAY PERMIT.

PROP. SEWER SVC. (4" PVC) 4. WATER METER TO BE SET BY THE CITY OF BOULDER.

'

.87

"W '00

9 S5

°11

0°4

TREES.

PROP. 3/4" TYPE K CU WATER SERVICE LINE

N3

MINIMUM OF 10 FEET FROM EXISTING AND PROPOSED

CORP. STOP W/ TAPPING SADDLE

55

5. ALL UTILITY MAINS AND SERVICES SHALL BE LOCATED A

0"W

CO

CLEANOUT

3/4" METER PIT (LOT SIDE, IN LANDSCAPING)

0'

SADDLE ON EXISTING MAIN.

5.0

MAIN TO RESIDENCE. CORPORATION STOP WITH TAPPING

WATER METER PIT (3/4")

12

GUNBARREL GREEN 12,500 SQ. FT. 0.29 AC +/-

6. WATER SERVICE: 3/4" TYPE K SOFT COPPER FROM 6" C.I.

M

9'0

LOT 29, BLOCK 41

7. SEWER SERVICE: 4" PVC (ASTM D3034) FROM RESIDENCE 15' HORIZONTAL SEPARATION (MIN 10' HORIZ. SEPARATION)

TO EXISTING SEWER STUB. MINIMUM SLOPE 1/8" PER FOOT (1.0%). CLEANOUT NEAR PROPERTY LINE. 8. EXISTING SEWER STUB LOCATION PER CITY OF BOULDER GIS DATA. VERIFY STUB LOCATION IN FIELD PRIOR TO

CONC. PAN EDGE AT 17.5' FROM PROPERTY LINE - NO SIDEWALK PER ILC

6' EA

.5'

R.

NO

EN

M

T

11. LEGAL DESCRIPTION: LOT 29, BLOCK 41, GUNBARREL

PROP/ 4" PVC (ASTM D3034) SEWER SERVICE LINE, MIN 1/8"/FT SLOPE

H

RT

M SE

REQUIREMENTS.

0'

AND CONSTRUCTION STANDARDS AND CDPHE

S.

O.

EA

5.0

AND SEWER SERVICES PER CITY OF BOULDER DESIGN

TY

12

AND 18-INCH VERTICAL SEPARATION BETWEEN WATER

(= W.

OP PR

17

ILI

0"E

10. MAINTAIN MINIMUM 10-FOOT HORIZONTAL SEPARATION

E IN

.L

UT

9'0

THE FIELD PRIOR TO CONSTRUCTION.

)

ND

0°4

CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS IN

S3

9. EXISTING UTILITY LOCATIONS ARE APPROXIMATE.

AG

AIN

DR

CONSTRUCTION.

7'

.1 53 0"ECO

CORP. STOP W/ TAPPING SADDLE

'0

°11

9 N5

CLEANOUT (LOT SIDE, IN LANDSCAPING)

GREEN SUBDIVISION, COUNTY OF BOULDER, STATE OF COLORADO. 12. SURVEY INFORMATION PER ILC BY HUEY SURVEYING LLC,

EX. SEWER STUB (VERIFY LOCATION IN FIELD)

IN

DATED 3-25-26. COLORADO REGISTERED LAND SURVEYOR

ER AT I. W

MA

.

"C

.6

NO. 38290.

EX

IN

ER EW

13. WATER METER LOCATED ON LOT SIDE OF PROPERTY LINE WITHIN LANDSCAPING PER B.R.C. 1981 SEC. 11.

"V

.P. .C

MA

S

8 X.

E

'R 60

14. SOUTH PROPERTY LINE COINCIDES WITH NORTH R.O.W.

.O .

.W

LINE PER ILC SURVEY. NO SIDEWALK EXISTS ALONG COTTONWOOD DRIVE FRONTAGE — CONCRETE PAN AT 17.5'

COTTONWOOD DRIVE

COTTONWOOD DR - 60' R.O.W. (BOULDER COUNTY)

60' R.O.W.

FROM PROPERTY LINE PER ILC SURVEY. 15. STANDARD DOMESTIC WATER SERVICE ONLY. NO FIRE

SCALE: 1" = 30' RIGHT-OF-WAY LINE

SERVICE LINE OR FIRE METER PROPOSED.

0'

UTILITY CONNECTION PLAN

PREPARED FOR:

SCALE: 1" = 30'

5083 Cottonwood Drive, Boulder County, Colorado Lot 29, Block 41, Gunbarrel Green Subdivision

Sopris Development

DATE: MAY 9, 2026

Andrew Stevens

SHEET: 1 OF 1

6420 Gunpark Drive, Suite D Outside City Utility Permit Application City of Boulder, Colorado

Boulder, CO 80301

REVISION 1

30'

60'